FixVault

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.

[Rotor] 

  1. Check that there is continuity between the slip rings (C).
    G11949919Courtesy of
  2. Check that there is no continuity between the slip rings and the rotor (B) or rotor shaft (A).
  3. If the rotor fails either continuity check, replace the alternator.

[Stator] 

  1. Check that there is continuity between each pair of leads (A).
    G11949920Courtesy of
  2. Check that there is no continuity between each lead and the coil core.
  3. If the coil fails either continuity check, replace the alternator.