Oil Pump: Inspection

Measure inner rotor-to-outer rotor radial clearance. Measure housing-to-outer rotor axial clearance. Inspect both rotors and pump housing for scoring and other damage. Replace components if clearance measurements are not within specification. See OIL PUMP SPECIFICATIONS  table.

OIL PUMP SPECIFICATIONS

Application In. (mm)
Inner Rotor-To-Outer Rotor
Radial Clearance
Standard (New) .002-.006 (.05-.15)
Service Limit .008 (.20)
Housing-To-Outer Rotor
Axial Clearance
Standard (New) .001-.003 (.03-.08)
Service Limit .006 (.15)
Housing-To-Outer Rotor
Radial Clearance
Standard (New) .004-.007 (.10-.18)
Service Limit .008 (.20)