GS & LS Models
- Unplug connector from recirculation control motor. Connect battery voltage to terminal No. 3 on recirculation control motor. See Figure . Ground terminal No. 2. Using jumper wire, connect terminals No. 1 and 2 together. With fresh/recirculation door in recirculated position, motor should rotate 1/2 turn and stop.
- Connect terminals No. 2 and 4 together. With fresh/recirculation door in fresh position, motor should rotate 1/2 turn and stop. If motor operation is not as specified, replace recirculation control motor.