One Or Both Mirrors Inoperative
- Turn ignition switch to ON position. Using a voltmeter, check for battery voltage between power mirror switch connector terminal "I" (Black/Yellow wire) and ground. See Figure . If battery voltage does not exist, check for blown fuse No. 13 or open in Black/Yellow wire. If battery voltage exists, go to next step.
- Turn ignition switch to OFF position. Using an ohmmeter, check continuity between power mirror switch connector terminal "J" (Black wire) and ground. If no continuity exists, repair open in Black wire.