Alternator Brush
- Remove end cover, then take out brush holder by removing its 2 screws. See Fig 1 .
- Measure length of brushes with a vernier caliper.ALTERNATOR BRUSH LENGTH
Application Length Standard 10.5 mm (0.41") Service Limit 35 mm (0.14") NOTE: If brushes are not inside service limit, replace brush holder assembly.