Preliminary Checks

Disable air bag system. See the AIR BAG RESTRAINT SYSTEM article. Remove instrument cluster from instrument panel. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Disconnect instrument cluster Green 22-pin "A" connector and Green 30-pin "B" connector. Check for bent, corroded, loose or disconnected terminals in connectors. Repair connectors as necessary and recheck system. See WIRING DIAGRAMS  . If all safety indicator input tests are okay, replace instrument cluster printed circuit board. See Fig 1 and see WIRING DIAGRAMS  .

Fig 1: Safety Indicator Unit Input Testing
G96I06633Courtesy of AMERICAN HONDA MOTOR CO., INC.