FixVault

Hazard Warning Switch

Remove instrument cluster assembly. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Remove hazard warning switch. Check for continuity between specified switch terminals with switch in ON and OFF position. See HAZARD WARNING SWITCH CONTINUITY  table. See Fig 1 . If continuity is not as specified, replace hazard warning switch. If continuity is as specified, check turn signal/hazard relay input. See TURN SIGNAL/HAZARD RELAY INPUT  under SYSTEM TESTS.

HAZARD WARNING SWITCH CONTINUITY

Switch Position (1) Check Continuity Between Terminals No.
Off 5 & 10; 6 & 7
On 1, 2 & 3; 5 & 9; 6 & 7
(1) Illumination bulb is positioned between terminals No. 6 and 7. Replace illumination bulb and retest before replacing switch.
Fig 1: Identifying Hazard Warning Switch Terminals
G00015412Courtesy of AMERICAN HONDA MOTOR CO., INC.