FixVault

Description & Operation

Generator uses 6 positive diodes and 6 negative diodes to rectify current. An internal Integrated Circuit (IC) voltage regulator controls charging system voltage. Amperage rating for generator is 130 amps.

CAUTION: Before disconnecting battery, obtain anti-theft code for radio. After battery is reconnected, the word CODE will appear on radio display. Enter 5-digit anti-theft code using select buttons and radio will begin working. If code is entered wrong too many times, leave radio on at least one hour and enter code correctly. Any time radio power is lost, pre-selected radio stations will have to be set.