FixVault

Trip Meter Select/Reset Switch

Remove instrument cluster assembly. See INSTRUMENT CLUSTER  under REMOVAL & INSTALLATION. Disconnect trip meter select/reset switch 5-pin connector. Check for continuity between specified switch terminals with switch in each specified position. See TRIP METER SELECT/RESET SWITCH CONTINUITY  table. If continuity is not as specified, replace trip meter select/reset switch.

TRIP METER SELECT/RESET SWITCH CONTINUITY

Trip Meter Select/Reset Switch Position (1) Check Continuity Between Terminals No.
Select (ON) 1 & 2; 4 & 5
Reset (ON) 2 & 3
(1) Illumination bulb is positioned between terminals No. 4 and 5. Replace illumination bulb and retest before replacing switch.