Trip Meter Select/Reset Switch
Remove instrument cluster assembly. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Disconnect trip meter select/reset switch 5-pin connector. Check for continuity between specified switch terminals with switch in each specified position. See TRIP METER SELECT/RESET SWITCH CONTINUITY table. If continuity is not as specified, replace trip meter select/reset switch.
TRIP METER SELECT/RESET SWITCH CONTINUITY
| Trip Meter Select/Reset Switch Position | (1) Check Continuity Between Terminals No. | ||
|---|---|---|---|
| Select (ON) | 1 & 2; 4 & 5 | ||
| Reset (ON) | 2 & 3 | ||
|
|||