FixVault

Without SCS Shorting

  1. Park the vehicle on a flat and level surface.
  2. With the ignition switch OFF, connect the HDS to the data link connector (DLC) (A) under the driver's side of the dashboard.
    Fig 1: Connecting HDS To DLC
    G05492200Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Turn the ignition switch ON (II).
  4. '07-08 models: Make sure the HDS communicates with the vehicle and the VSA modulator-control unit. If it doesn't, troubleshoot the DLC circuit (see '07-08 MODELS ).
  5. Do the VSA sensor neutral position memorization in the VSA ADJUSTMENT with the HDS.
    NOTE: See the HDS Help menu for specific instructions.
  6. Turn the ignition switch OFF.