Recirculation Control Motor Replacement
- Open the glove box. Remove the damper from the glove box, then let the glove box hang down (see
GLOVE BOX REMOVAL/INSTALLATION
).
- Remove the relays from the bracket.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the blower unit.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
- Install the motor in the reverse order of removal. Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.