FixVault

Countershaft Bearing Replacement

Special Tools Required 

  1. Remove the countershaft bearing from the torque converter housing using the adjustable bearing puller (25-40 mm) and a commercially available 3/8 "-16 slide hammer (A).
    Fig 1: Removing Countershaft Bearing From Torque Converter Housing
    G05495853Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Install the ATF guide plate (A) into the housing, then install the new bearing (B) in the direction shown.
    Fig 2: Installing New Bearinging Using ATF Guide Plate
    G05495854Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Install the bearing (A) in the housing using the driver and the attachment (78 x 80 mm); install the bearing outer notch-cut (B) to a depth (C) of 0-0.03 mm (0-0.001 in.) below the housing surface (D).
    Fig 3: Tapping Bearing Into Housing
    G05495855Courtesy of AMERICAN HONDA MOTOR CO., INC.