FixVault

Enable Conditions

ENABLE CONDITIONS

Condition Minimum Maximum
Engine speed - 4,400 rpm(1)
4,600 rpm(2)
Battery voltage 10.5 V -
Commanded EGR valve lift 0.012 in. (0.3 mm) -
No active DTCs P0107, P0108, P0112, P0113, P0117, P0118, P0134, P0135, P0154, P0155, P0300, P0301, P0302, P0303, P0304, P0305, P0306, P0335, P0339, P0401, P0406, P1128, P1129, P1172, P1174, P2195, P2197, P2237, P2238, P2240, P2241, P2243, P2245, P2247, P2249, P2251, P2252, P2254, P2255, P2627, P2628, P2630, P2631
(1) J32A3 engine
(2) J35A8 engine