Gauge Control Module Replacement

NOTE: Before replacing the gauge control module, do the "Rewriting the ODO Data on a New Gauge Control Module" (see REWRITING THE ODO DATA ON A NEW GAUGE CONTROL MODULE  ).
  1. Remove the instrument panel (see INSTRUMENT PANEL REMOVAL/INSTALLATION ).
  2. Remove the screws from the gauge control module (A), and spread a protective cloth (B) on the upper column cover.
    Fig 1: Identifying Gauge Control Module
    G05462800Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Disconnect the connectors (C), and remove the gauge control module.
  4. Install the gauge in the reverse order or removal.