FixVault

Enable Conditions

ENABLE CONDITIONS REFERENCE CHART

Condition Minimum Maximum
Battery voltage 6.0 V -
Ignition switch ON (II)
No active DTCs P0122, P0123, P0222, P0223, P2101, P2118, P2122, P2123, P2127, P2128, P2135, P2138
Other Engine is stopped and ignition switch is not in ON (II)