Electronic Control System: Self-diagnosis
If the PCM detects the failure of a signal from a sensor, a switch, a solenoid valve or from another control unit, it stores a Temporary DTC or a DTC Depending on the failure, a DTC is stored in either the first or the second drive cycle When a DTC is stored, the PCM blinks the D indicator and/or turns on the malfunction indicator lamp (MIL) by a signal sent to the gauge control module via F-CAN
- One Drive Cycle Detection Method
When an abnormality occurs in the signal from a sensor, a switch, a solenoid valve, or from another control unit, the PCM stores a DTC for the failure and blinks the D indicator and/or turns on the MIL immediately
- Two Drive Cycle Detection Method
When an abnormality occurs in the signal from a sensor, a switch, a solenoid valve, or from another control unit in the first drive cycle, the PCM stores a Temporary DTC The D indicator and the MIL do not turns on at this time If the failure continues in the second drive cycle, the PCM stores a DTC and blinks the D indicator and/or turns on the MIL