FixVault

CMP Sensor B Replacement

  1. Disconnect the connector (A) and hoses (B) from the EVAP canister purge valve (C), then remove the EVAP canister purge valve assembly
    Fig 1: Connector, Hoses, EVAP Canister Purge Valve With Torque Specification
    G05992358Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Disconnect the CMP sensor B connector (A)
    Fig 2: CMP Sensor B Connector, O-Ring With Torque Specification
    G05992359Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. Remove CMP sensor B
  4. Install the parts in the reverse order of removal with a new O-ring (C).