FixVault

EVAP Canister Purge Valve Replacement

NOTE: DTC P0443 may be stored if the EVAP canister purge valve connector is disconnected within 15 seconds after the ignition switch is turned to LOCK (0).
  1. Remove the air cleaner (see AIR CLEANER REMOVAL/INSTALLATION ).
  2. Remove the air bypass outlet pipe (see CHARGE AIR COOLER REMOVAL AND INSTALLATION ).
  3. Disconnect the CMP sensor B 3P connector (A).
    Fig 1: CMP Sensor B 3P Connector, EVAP Canister Purge Valve 2P Connector And Hoses With Torque Specifications
    G08059820Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Disconnect the hoses (B) and EVAP canister purge valve 2P connector (C).
  5. Remove the screws (D), then remove the EVAP canister purge valve (E).
  6. Install the parts in the reverse order of removal.