FixVault

Sunlight Sensor Test

NOTE: Before testing the sensor, check for HVAC DTCs (see GENERAL TROUBLESHOOTING INFORMATION )
  1. Remove the sunlight sensor (A) (see Sunlight Sensor Replacement  )
    Fig 1: Identifying Sunlight Sensor
    G05988682Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Turn the ignition switch to ON (II) Measure the voltage between terminals with the (+) probe on terminal No 2 and the (-) probe on terminal No 1 with the connector connected
    NOTE: The voltage readings do not change under the light of a flashlight or a fluorescent lamp Voltage should be
    • 3.6-3.7 V or more with the sensor out of direct sunlight
    • 3.3-3.5 V or less with the sensor in direct sunlight
  3. If the voltage is not as specified, replace the sunlight sensor (see Sunlight Sensor Replacement )