Front Mode Control Motor Test
NOTE:
Before testing, check for HVAC DTCs (see HOW TO CHECK FOR DTCS WITH THE HDS
).
- Disconnect the 7P connector from the front mode control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT
).NOTE: Incorrectly applying power and ground to the front mode control motor will damage it. Follow the instructions carefully.
- Connect battery power to terminal No. 1 of the front mode control motor, and ground terminal No. 2; the front mode control motor should run smoothly, and stop at Vent. If it doesn't, reverse the connections; the front mode control motor should run smoothly, and stop at Defrost. When the front mode control motor stops running, disconnect battery power immediately.
- If the front mode control motor did not run in step 2, remove it, then check the front mode control linkage and doors for smooth movement.
- If the linkage and doors move smoothly, replace the front mode control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).
- If the linkage or doors stick or bind, repair them as needed.
- If the front mode control motor runs smoothly, go to step 4.
- Use a digital multimeter with an output of 1 mA or less at the 20 kΩ range. With the front mode control motor running as in step 2, check for continuity between terminals No. 3, No. 4, No. 5, and No. 6 and terminal No. 7 individually. There should be continuity for a moment at each terminal as the motor moves past the switch's terminal.
- If there is no continuity for a moment at each terminal, replace the front mode control motor (see RECIRCULATION CONTROL MOTOR REPLACEMENT ).