FixVault

Recirculation Control Motor Replacement: Installation

  1. Make sure the damper lever pins in the motor lever are visible through the holes.
    Fig 1: Identifying Damper Lever Pins In Motor Lever
    G08058031Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. While holding the recirculation control motor (A), install the self-tapping screws and connect the 7P connector (B).
    Fig 2: Locating Recirculation Control Motor, Self-Tapping Screws And 7P Connector
    G08058032Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. After installation, make sure the motor runs smoothly.