Oil Pump Overhaul: Inspection
NOTE:
Refer to the EXPLODED VIEW if needed during this procedure.
- Remove the screws from the pump housing, then separate the housing and cover.
- Check the inner rotor-to-outer rotor radial clearance between the inner rotor (A) and the outer rotor (B). If the inner rotor-to-outer rotor radial clearance exceeds the service limit, replace the oil pump assembly.
Inner Rotor-to-Outer Rotor Radial Clearance
Standard (New): 0.04-0.14 mm (0.0016-0.0055 in)
Service Limit: 0.20 mm (0.0079 in)
- Check the pump housing-to-rotor axial clearance between the rotors (A) and the pump housing (B). If the pump housing-to-rotor axial clearance exceeds the service limit, replace the oil pump assembly.
Pump Housing-to-Rotor Axial
Clearance
Standard (New): 0.02-0.07 mm (0.0008-0.0028 in)
Service Limit: 0.12 mm (0.0047 in)
- Check the pump housing-to-outer rotor radial clearance between the outer rotor (A) and the pump housing (B). If the pump housing-to-outer rotor radial clearance exceeds the service limit, replace the oil pump assembly.
Pump Housing-to-Outer Rotor Radial
Clearance
Standard (New): 0.10-0.19 mm (0.0039-0.0075 in)
Service Limit: 0.20 mm (0.0079 in)
- Inspect both rotors and the pump housing for scoring or other damage. Replace the parts, if necessary.
- Apply liquid thread lock to the pump housing screws, then install the oil pump cover.
- Make sure the oil pump turns freely.