Switch Test/Replacement
- Remove the center console panel (see CENTER CONSOLE PANEL REMOVAL/INSTALLATION ).
- Disconnect the 16P [12P] connector from the seat ventilation switch (A).
[]: Front passenger's seat ventilation switch
- Remove the two screws and the switch.
- Check for continuity between the terminals in each switch position according to the table.NOTE:
- Make sure the correct test lead (+ or -) is placed on the terminal.
- When checking for continuity across the diode, use the diode setting (→|-) on the digital volt/ohm meter to check the diode bias.
- Note this important operating characteristic; diode bias causes a diode to fully conduct electricity in one direction (forward), while not at all in the opposite direction (reverse).
- If the continuity check is not as specified, replace the seat ventilation switch.
- Install the parts in the reverse order of removal.