FixVault

Rocker Arm Oil Pressure Switch Removal/Installation

  1. Disconnect the rocker arm oil pressure switch connector (A).
    Fig 1: Rocker Arm Oil Pressure Switch, Connector And O-Ring With Torque Specifications
    G07767901Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Remove the rocker arm oil pressure switch (B).
  3. Install the parts in the reverse order of removal with a new O-ring (C).