DTC C0049-7B: Inspection
BRAKE_LEVEL_SW Shorted Wire Inspection
Test Procedure
- Preparation
-
- -
Brake fluid level switch 2P connector: disconnected
- -
Gauge control module connector A (32P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
NOTE: Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
| (Disconnected) Brake fluid level switch 2P connector female terminals | ||||
| IG Mode |
|
Normal Conditions | ||
| BRAKE_LEVEL_SW shorted to ground inspection | OFF | Not shorted |
Results
- If abnormal, there is a problem in the circuit.
VSA Modulator-Control Unit Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining VSA modulator-control unit is the cause.
Results
- There is a problem with the VSA modulator-control unit.