FixVault

Fuel Tank Draining: Drain

How to use this manual .

WARNING: Flammable - Keep Fire Away

NOTICE: 

Refer to the Fuel and Emissions Systems Service Precautions  before doing the procedure.

  1. Fuel Tank - Drain

    Preconditions 

    Figure 1 

    GHH561670Courtesy of HONDA, U.S.A., INC.

    Procedure 

    1. Disconnect the quick-connect fitting (a) . (Figure 1)

    NOTICE: 

    Place a rag or shop towel (b) over the quick-connect fitting.

    Figure 2 

    GHH561671Courtesy of HONDA, U.S.A., INC.

    2. Using a T-fitting (c) and suitable hoses, connect a vacuum pump/gauge, 0-30 inHg, to the fuel tank unit port (d). (Figure 2)3. Do the 12 volt battery terminal reconnection procedure .

    4. Attach another suitable hose to the T-fitting and place the other end of the hose to a suitable gasoline container (e), then reconnect the connectors (f). (Figure 2)5. Apply constant vacuum pressure to drain the fuel out of the fuel tank.

    NOTICE: 

    • To avoid damaging the fuel tank unit, do not apply vacuum of more than 25 inHg (85 kPa).
    • If you are removing the fuel tank unit, drain the fuel until the fuel tank is at or below 3/4.
    • If you are removing the fuel tank, drain the fuel until the fuel tank is empty as necessary.