FixVault

Testing & Repair: Brushes

Check that brushes are longer than 7/32" (6 mm), replace if necessary. Unsolder brushes from voltage regulator. Solder the new brushes. Do not allow any solder to run into strands of brush leads. Brush must be free to slide in holder with normal spring tension of 10-14 ozs. (283-397 g).