Without disturbing test leads, disconnect field lead from alternator terminal, connect jumper wire between this terminal and field rheostat terminal, connect other field rheostat terminal to alternator output terminal. With battery adapter switch open, rotate field rheostat knob fully clockwise to "direct" position. Ammeter will indicate field current of approximately 2 amperes (see Field Current Specifications). If ammeter reading is low, defective brushes or rotor field winding is indicated. Rotate field control rheostat back to full counterclockwise or open position before disconnecting test leads.Alternator Specifications
| Alternator No. |
Amperes |
Volts |
| ALK-6309, 6310, 6311 |
35 |
14.2 |
| ALE-6305, 6306 |
40 |
14.2 |
| Am. Mot. 31 95534(5) |
35 |
14.2 |
Alternator Field Current
| Alternator No. |
Amperes |
Volts |
| ALK-6309, 6310, 6311 |
.2.3-2.4 |
10.0 |
| ALE-6305, 6306 |
2.4-2.5 |
10.0 |
| Am. Mot. 3195534(5) |
2.4-2.5 |
10.0 |