FixVault

Ignition Timing

Initial ignition timing is controlled by the ignition module and is not adjustable.

NOTE: Engines are equipped with a receptacle for a magnetic probe timing light, located 9.5° ATDC. Do not use this receptacle with a normal timing light.
Fig 1: 1.4L Firing Order & Distributor Location
G50D01633
Fig 2: 1.7L Firing Order & Distributor Location
G2217
IGNITION TIMING SPECIFICATIONS

Application Degrees BTDC @ RPM
All Engines (1) 8 @ 700
(1) Initial timing is not adjustable.