FixVault

Valve Guide Servicing

  1. Check guides for wear with suitable tool (Tool No. 10-216). If reject end of tool can be inserted, replace valve guide. Using suitable tool (Tool No. 10-206), warm cylinder head to 176-210°F and press guide out top of cylinder head.
  2. Press new guide in from top of cylinder head until it measures 2.23" from top of cylinder head to top of guide. Using suitable reamer (Tool No. 10-215), ream guide to proper size. Reface valve seat and valve.