FixVault

Alternative Hall Sending Unit Operation Check

  1. Disconnect high tension wire at distributor and connect it to ground. Connect a test light (4-24V) between terminal 1 and 15 of ignition coil. Crank engine with starter for approximately 5 seconds.
  2. Test light must flicker. If not, replace Hall sending unit in distributor.