FixVault

Technical data

Engine identification  AMU 
Idle speed
Engine speed cannot be adjusted, it is regulated by idle stabilization
700 to 820 RPM
Engine speed (RPM) limitation
Via fuel injector shut-off
about 6800 RPM
Ignition timing is determined in the control module
It is not possible to adjust the ignition timing
 
Ignition system Single coil ignition system with 4 ignition coils (power output stages integrated) that are connected directly to spark plugs via the ignition cables.
Spark plugs Tightening torque 30 Nm.
Firing sequence    1-3-4-2