FixVault

Drive Plate With Overload Protection, Checking Run-Out And Adjusting

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2018 Audi S7, 2018 Audi RS 7, 2018 Audi A7 Quattro, 2017 Audi S7, and 2017 Audi RS 7. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:

May only be removed when refrigerant circuit is opened or has been discharged; bring vehicle to a shop that has the necessary tools and in which the work can be performed accordingly by qualified personnel. Refer to REFRIGERANT CIRCUIT .

Special tools and workshop equipment required 

Procedure

-- Remove the A/C compressor. Refer to A/C COMPRESSOR, REMOVING AND INSTALLING, 8-CYLINDER FSI/TFSI ENGINE .

-- Clean the drive plate flange -A-.

GWWA87-0624Courtesy of AUDI OF AMERICA, LLC

-- Secure the gauge -B- to the A/C compressor with the Dial Gauge Holder:VW387  -C-.

-- Attach the dial gauge probe -D- to the drive plate flange with a pre-tensioning of approximately 1.0 mm and set the gauge to "0".

-- Turn the A/C compressor drive unit -E- a few turns.

-- If the run-out deviation is greater than 0.2 mm, repeat the adjustment for the drive plate. Refer to DRIVE PLATE WITH OVERLOAD PROTECTION, REMOVING AND INSTALLING .