FixVault

Check Valve, Checking

NOTE:

The check valve is tightly installed in the vacuum hose.

To check it, the vacuum hose must be removed.

Valve must allow air to flow in direction of -arrow-.

Valve must remain closed in opposite direction.

Observe correct installation position.

The flow direction arrow faces the vacuum pump.