FixVault

Rearview Camera -R189-, CALIBRATING

-- Establish the requirements Calibration Unit => Calibration Requirements .

-- Connect the Vehicle Diagnostic Tester.

:VAS6350/1  installing:

-- Check the dimension of the holes.

-- Equip the :VAS6350/1  appropriately. Use spacer pieces.

-- To do so, secure three wheel bolt adapters in the hole circle to each :VAS6350/1  .

-- Place the paddle on both :VAS6350/1  and secure them using a clamping screw.

-- Place the :VAS6350/1  onto the wheel bolts on the rear wheels.

The :VAS6350/1  are positioned by the "O-rings" in the adapters and secured.

GWWN94-10685Courtesy of AUDI OF AMERICA, LLC
NOTE:

Attach the :VAS6350/1  onto the wheels so that any installed "anti-theft" wheel mounting bolts are not connected to the :VAS6350/1  .

-- Adjust the paddles with aid of lock bolts so that they move freely just above the floor. Check the paddles for ease of movement.

-- Install and align the :VAS6350A  . Refer to Calibration Unit .

Distance measurement: 

-- Switch on the :VAS6350/2  .

GWWA91-12101Courtesy of AUDI OF AMERICA, LLC

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

-- Hold the :VAS6350/2  -2- flush in the bracket on one side of the calibration board (attach with rear edge). The :VAS6350/2  -2- must sit securely on the bracket.

GWWN94-10684Courtesy of AUDI OF AMERICA, LLC

-- Press the measuring button briefly.

The laser switches on.

-- Make sure that laser beam from :VAS6350/2  -2- hits lower, enlarged part of paddle -1-.

If this is not the case, the paddles must be corrected accordingly via clamping screws on the :VAS6350/1  .

-- Use one hand to secure the :VAS6350/2  in the bracket on the :VAS6350  while the laser beam is visible on the paddle.

-- Then press the measurement button for the distance measurement briefly.

-- Write down the value.

-- Repeat this measurement on the other side of the :VAS6350  in the same way for the rear wheel.

The distance value must be the same on both sides.

If values are not identical:

-- Align the :VAS6350A  long enough so that both sides are identical.

Pay attention when aligning the :VAS6350  , that the :VAS6350/3  from the :VAS6350  strikes the center of the Audi rings and the indicator of the level remains centered. Adjust if necessary.

Measurement -dimension H- :

-- Measure the height of the :VAS6350  , -dimension H- (top edge platform - floor).

GWWA91-11140Courtesy of AUDI OF AMERICA, LLC

Make sure the :VAS6350/2  is adjusted correctly (attach with front edge).

The display shows how to stop the :VAS6350/2  . Press the corresponding button.

GWWA91-12100Courtesy of AUDI OF AMERICA, LLC
  1. Attach with front edge
  2. Attach with rear edge

Enter the height and distance dimensions into the Vehicle Diagnostic Tester in "millimeters".

Calibrating 

The Vehicle Diagnostic Tester is connected.

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Press the Select individual tests  button and select the following one after the other:

From here, the Vehicle Diagnostic Tester advances the calibration procedure forward.

WARNING:

Make sure light does not reflect off the calibration board.

Reflections affect the Rearview Camera -R189- and may make it impossible to perform the calibration.