Night Vision System, Calibrating, Audi Q7: Notes
Special tools and workshop equipment required
- Vehicle Diagnostic Tester
- Wheel Alignment Computer
- Calibration Tool - Linear Laser - VAS6350/3A- (can be used from the Calibration Tool - VAS6350-)
- Setting Device - Basic Set - VAS6430/1- or Setting Device - Basic Set - VAS6430/1A-
- Night Vision Calibration Tool - VAS6430/6-
- Adapter VAS6430/9 - VAS6430/9-, only for surface mounted hoist with a dimension greater than 300 mm.
- If the vehicle has an adaptive cruise control and night vision system, then the night vision system must be adjusted/calibrated first and after that can the adaptive cruise control be adjusted.
- Check the DTC memory and correct any malfunctions before beginning the calibration.
- If the -VAS6430/3- is located on the calibration beam of the - VAS6430/1A- or -VAS6430-, it must be removed.
- Check if the Night Vision System Camera - R212- fits correctly in the bracket and the viewing range for the camera is not blocked.
- Make sure the protective window on the Night Vision System Camera - R212- is not chipped. Replace it if necessary.
- Check of the visible area of the Driver Assistance Systems Front Camera - R242- is free. -->
- "Activate wheel change mode" on equipment versions with air suspension. Refer to Owner's Manual or "Standard Vehicle Height, Initiating and Locking". Refer to Standard Vehicle Height, Initiating and Locking