Peripheral Camera System, Calibrating
WARNING: This page does not describe the selected car, but rather 6 other vehicles, including the 2022 Audi SQ5, 2022 Audi Q5 e, 2022 Audi Q5, 2021 Audi SQ5, and 2021 Audi Q5 e. However, it is still accessible from the selected car via links, so may be relevant.
-- The vehicle must be on a level surface.
-- Roll out the :VAS721001 at the left and right near the vehicle.
-- Install the rear and front clamping strip on the :VAS721001 .
-- Align the crosshairs -2- to the front axle of the vehicle (center front wheel).
-- Align both calibration devices parallel. The vehicle must be located in the center between both calibration devices.
Pay attention to the following measurement requirements:
- Dimension -a- 2000 to 2500 mm ± 5 mm, front and rear the same
- The dimension -b- must be the same on both sides
- The dimension -c- must be the same on both sides
-- Set-up the requirement for the vehicle. Refer to Requirement for the Calibration of the Vehicle .
Calibrating Procedure
The Vehicle Diagnostic Tester is connected.
-- Perform the calibration. Refer to Vehicle Diagnostic Tester in the "Guided Functions " mode.