Peripheral Camera System, Calibrating

WARNING: This page is about a different car, the 2019 Audi S5 Sportback, 2019 Audi RS 5 Sportback, 2019 Audi A5 Sportback, 2018 Audi S5 Sportback, and 2018 Audi A5 Sportback. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

-- The vehicle must be on a level surface.

NOTE:

The vehicle in the illustration is only a basic outline.

GWWA91-12470Courtesy of AUDI OF AMERICA, LLC

-- Roll out the : VAS721001  at the left and right near the vehicle.

-- Install the rear and front clamping strips on the : VAS721001  .

-- Align the crosshairs -2- to the front axle of the vehicle (center front wheel).

-- Align both calibration devices parallel. The vehicle must be located in the center between both calibration devices.

Pay attention to the following measurement requirements:

-- Set-up the requirement for the vehicle. Refer to Calibration System: VAS721001, INSTALLING AND ALIGNING - Calibration Requirements on Vehicle .

-- Connect the Vehicle Diagnostic Tester.

Calibrating Procedure 

-- Select the Diagnostic  mode and start the diagnosis.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

From here, the Vehicle Diagnostic Tester advances the calibration procedure forward.