FixVault

Peripheral Camera, Calibrating

WARNING: This page does not describe the selected car, but rather 10 other vehicles, including the 2022 Audi SQ8, 2022 Audi RS Q8, 2022 Audi Q8, 2021 Audi SQ8, and 2021 Audi RS Q8. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Calibration/Adjustment Must be Performed if:

Preparing for Calibration

GWWA91-12469Courtesy of AUDI OF AMERICA, LLC
  1. Left Calibration Device
  2. Front Peripheral Camera -R243-
  3. Right Calibration Device
  4. Right Peripheral Camera -R245-
  5. Rear Peripheral Camera -R246-
  6. Left Peripheral Camera -R244-

Preliminary Work

Procedure 

-- Roll out the : VAS721001  at the left and right near the vehicle.

-- The arrows -1- on the : VAS721001  point in the direction of travel.

GWWA91-12470Courtesy of AUDI OF AMERICA, LLC

-- Install the rear and front clamping strips on the : VAS721001  .

-- Align the crosshairs -2- on the : VAS721001  to the front axle of the vehicle (center of front wheel).

-- Align both calibration devices parallel. The vehicle must be located in the center between both calibration devices.

Pay attention to the following measurement requirements:

Calibration Procedure 

The following should not occur during the calibration procedure:

-- Connect the Vehicle Diagnostic Tester.

-- Switch the ignition on.

-- Select and start the Diagnostic  operating mode.

-- Select the Test plan  tab.

-- Select the Select individual test  button and select the following tree structure consecutively:

-- Start the selected program and follow the instructions on the Vehicle Diagnostic Tester display.

-- Switch off the ignition after successful calibration/adjustment.

-- Disconnect the Vehicle Diagnostic Tester from the diagnostic connection.

-- Disconnect the battery charger. Refer to BATTERY, CHARGING .