Auxiliary Air Valve
NOTE:
Replacement of auxiliary air valve requires that immediate replacement be available or draining cooling system below level of valve.
Disconnect battery ground cable. Remove electrical connector and air hoses from air valve. Remove 2 bolts securing valve to cylinder head and remove valve. To install, reverse removal procedure.