Heating And A/C Control Module X610 Connector End View
Pin Assignments At Plug Connector X610
| Pin | Type | Description /Signal type | Connection /Measuring notes |
|---|---|---|---|
| 1 | Not used | ||
| 2 | A | Pressure sensor signal, air conditioning system | Pressure sensor, air conditioning system |
| 3 | Not used | ||
| 4 | Not used | ||
| 5 | Not used | ||
| 6 | Not used | ||
| 7 | A | Supply, A/C pressure sensor | Pressure sensor, air conditioning system |
| 8 | E/A | K-bus signal | Control module for instrument cluster |
| 9 | E | Terminal 30 | Relay, A/C compressor |
| 10 | A | Electronic ground, A/C pressure sensor | Pressure sensor, air conditioning system |
| 11 | Not used | ||
| 12 | Not used | ||
| 13 | M | Ground | Ground point |
| 14 | M | Ground | Ground point |
| 15 | Not used | ||
| 16 | Not used | ||
| 17 | Not used | ||
| 18 | Not used |