Initialization Of Power Windows
INITIALIZATION OF POWER WINDOWS
| Front Windows | Rear Windows |
|---|---|
| On Initial start-up, only the upper window stop has to be learned. For this purpose the window must be held for 500ms at the upper stop position. Move window to full closed position and hold for at least 500ms. |
The rear windows must be initialized. During the initialization the end positions of the window travel are determined by limit runs into the upper window seal and to the lower window stop. Move window to full closed position and hold for at least 500ms. Move window to lower window stop and hold for 17 seconds. Move window to full closed and continue to hold the switch in the window closing direction. The Window will open the close to confirm proper initialization. note: This procedure is the same as E65. |