FixVault

Float Level

  1. Remove air horn. Turn air horn up-side down. Allow weight of float to rest on top of needle. Leave gasket in place. See  Fig 1  .
  2. Using a depth or "T" scale, measure distance from air horn gasket to index point at toe of float.
  3. If adjustment is needed, gently bend float arm up or down. Do not force needle against needle seat.
Fig 1: Adjusting Float Level
G09320014Courtesy of GENERAL MOTORS COMPANY