FixVault

Test E: Lock Out Switch Test

  1. With ignition switch in RUN position and lock out switch OFF, connect test lamp at the following master switch connector wires. Leave master switch connector connected.
  2. Connect test lamp between C2/A (Pink wire) and ground. The test lamp should light. If not, check for a poor connection. If OK, replace master switch.
  3. Lock the lock out switch. Connect test lamp between C2/A (Pink wire) and ground. The test lamp should not light. If lamp lights, check Pink wire (Circuit 76) for a short to battery. If OK, check for a poor connection. If OK, replace master switch.