Test E: Lock Out Switch Test
- With ignition switch in RUN position and lock out switch OFF, connect test lamp at the following master switch connector wires. Leave master switch connector connected.
- Connect test lamp between C2/A (Pink wire) and ground. The test lamp should light. If not, check for a poor connection. If OK, replace master switch.
- Lock the lock out switch. Connect test lamp between C2/A (Pink wire) and ground. The test lamp should not light. If lamp lights, check Pink wire (Circuit 76) for a short to battery. If OK, check for a poor connection. If OK, replace master switch.