FixVault

Diagnostic Aids

Because coil driver gets its power from coil, check ignition feed circuit to ignition coil for opens.

Fig 1: Code 41 Schematic (5.7L) Opti-spark Ignition System Open Or Shorted EST Circuit
G94D34077
Fig 2: Code 41 Flow Chart (5.7L) Opti-spark Ignition System Open Or Shorted EST Circuit