Conditions For Setting DTC
- The generator turn on signal circuit voltage is low while the PCM is commanding the generator on.
- The above condition is present for more than 30 seconds.
- The generator field duty cycle signal PWM is less than 5 percent.
- The engine RPM is less than 2500.
- The above conditions are present for more than 30 seconds.