Installation Procedure
- Ensure the cable lock button is in the UP position.
- Ensure the shift lever is in the PARK position.
- Install the park/lock cable.
- Snap the cable connector into the shifter base.
- Install the cable retainer to the park/lock cable at the shift control.
- Ensure that the ignition key is in the RUN position.
- Snap the cable into the inhibitor housing.
- Turn the ignition key to the LOCK position.
- Snap the cable end onto the shifter park lock lever pin.
- Push the cable connector nose forward in order to remove the slack.
- Snap the cable connector lock button down using no load applied to the connector nose.
- Inspect the functional operation of the park/lock cable. Refer to Park Lock Cable Adjustment .
- Install the knee bolster. Refer to Knee Bolster Replacement in Instrument Panel, Gages and Console.
- Install the front floor console. Refer to Console Replacement - Front Floor in Instrument Panel, Gages and Console.
- Connect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure in Engine Electrical.
IMPORTANT:
Ensure that the ignition key is in the LOCK position. Do NOT attempt to insert the cable with the key in any other position.