FixVault

Installation Procedure

    Fig 1: Oiling Male Pipe Ends (Metal Collar)
    GM12784Courtesy of GENERAL MOTORS CORP.
    CAUTION: Always apply a few drops of clean engine oil to the male pipe ends before connecting the fuel pipe fittings in order to reduce the risk of fire and personal injury. This will ensure proper reconnection and prevent a possible fuel leak. During normal operation, the O-rings located in the female connector will swell and may prevent proper reconnection if not lubricated.
  1. Apply a few drops of clean engine oil to the male pipe end.
  2. Fig 2: Assembling Connectors (Metal Collar)
    GM12786Courtesy of GENERAL MOTORS CORP.
  3. Push both sides of the fitting together to cause the retaining tabs to snap into place.
  4. Fig 3: Removing/Installing Retainer At Quick-Connect Fitting
    GM730719Courtesy of GENERAL MOTORS CORP.
  5. Once installed, pull on both sides of the fitting to make sure the connection is secure.
  6. If applicable, install the quick connect fitting retainer (1).