FixVault

Repair Verification

  1. Ignition ON, seal the EVAP system with a scan tool.
  2. Turn the nitrogen/smoke valve on the J 41413-200  to nitrogen. See Special Tools .
  3. IMPORTANT: DO NOT exceed the specified value in this step. Exceeding the specified value may produce incorrect test results.
  4. Use the remote switch to activate the J 41413-200  and pressurize the fuel tank with nitrogen to 5 inches H2O. See Special Tools .
  5. While observing the FTP sensor parameter with a scan tool, command the EVAP vent valve OFF.
  6. Verify the FTP Sensor parameter is 0 inches H2O.