  1. Remove the fuel fill cap. Connect the GE-41415-50  to the fuel tank filler neck. Connect the J 41413-200  to the GE-41415-50  . See Special Tools .
  2. Seal the EVAP system with the scan tool Purge Seal function.
  3. Pressurize the EVAP system with nitrogen to 5 inches H2O. Compare the Fuel Tank Pressure Sensor parameter to the J 41413-200  pressure/vacuum gage. See Special Tools . The FTP sensor should be within 1 inch H2O of the pressure/vacuum gage.
    • If the FTP is not within 1 inch H2O of the pressure/vacuum gage, replace the FTP sensor.
  4. Command the vent solenoid valve OPEN with a scan tool.
    • If the FTP sensor parameter is not 0 inch H2O, replace the FTP sensor.